Enhanced Static Voltage Stability in Distribution Networks Through Coordinated DG and STATCOM Placement Using a Hybrid GWO-PSO Algorithm | ||
| AUT Journal of Electrical Engineering | ||
| مقالات آماده انتشار، پذیرفته شده، انتشار آنلاین از تاریخ 19 اسفند 1404 اصل مقاله (2.02 M) | ||
| نوع مقاله: Research Article | ||
| شناسه دیجیتال (DOI): 10.22060/eej.2026.24368.5693 | ||
| نویسندگان | ||
| Molla Addisu Mossie* 1؛ Tefera Terefe Yetayew2؛ Girmaw Teshager Bitew1؛ Teketay Mulu Beza1؛ Mezigebu Getinet Yenealem1 | ||
| 1Faculty of Electrical and Computer Engineering, Bahir Dar Institute of Technology, Bahir Dar University, Bahir Dar, P.O. Box 26, Ethiopia | ||
| 2Department of Electrical Power and Control Engineering, Adama Science and Technology University, Adama, P.O. Box 1888, Ethiopia | ||
| چکیده | ||
| This paper addresses voltage stability challenges in distribution networks through a coordinated approach using Distributed Generation (DG) and Static Synchronous Compensator (STATCOM) placement. A novel hybrid Grey Wolf Optimization-Particle Swarm Optimization (GWO-PSO) algorithm is proposed to optimize the placement and sizing of these components with the objective of enhancing static voltage stability. The Fast Voltage Stability Index (FVSI) is employed as the primary metric for assessing voltage stability, where lower values (approaching zero) indicate improved stability. The proposed hybrid algorithm leverages GWO's exploration capabilities and PSO's exploitation strengths to overcome the limitations of individual algorithms. The methodology is validated on a 35-bus distribution system with a total load demand of 1.89 MW and 1.3455 MVAr. Results show that the hybrid GWO-PSO achieves an average FVSI reduction of 16.98%, significantly outperforming both standalone GWO (12.45%) and PSO (14.32%) implementations. The voltage profile across all buses is substantially improved, with the hybrid approach maintaining voltages closer to nominal values of 1.0 p.u. compared to the base case where many buses operate under low voltage conditions. The hybrid algorithm demonstrates faster convergence, reaching optimal solutions within 100 iterations compared to individual GWO and PSO implementations. The coordinated placement strategy determined optimal DG and STATCOM sizes and locations, effectively addressing voltage stability concerns in distribution systems experiencing rapid load growth with insufficient reactive power support. | ||
| کلیدواژهها | ||
| Voltage stability assessment؛ DG؛ Fast voltage stability index؛ Hybrid GWO-PSO | ||
|